Product Guides
B3 — For shippers
Important: DO NOT remove the plastic bag unless you need USB access for final readings.
Start the device
- (Optional) Configure in the Cydiance App — or skip to use factory defaults.
- Press and hold 5 seconds until both LEDs light up, or start from the app while connected.
- For the first 30 minutes, the blue LED blinks twice every 2 seconds.
- After 30 minutes, the LED stops blinking to save battery.
- To confirm the logger is still active, press the button once. If the LED blinks, the device is running.
- While logging, a single press creates a MARK (up to 8 marks).
- Manual stop is not available.
Place in the shipment
When possible, use two loggers for the simplest temperature mapping:
- Place one at the container air outlet to record supply-air temperature from the refrigeration unit.
- Place one at the container door to capture temperature coverage across the load.
Keep each logger in its plastic bag during transport.
Receiving side
See B3 — For receivers.
Important
- DO NOT place the device near a fire; the battery can be dangerous.
- KEEP AWAY from babies, children, and pets; this device is not a toy.
- Consider our recycling program before disposing of the device.